  • Refund will be given as: Money back or replacement (buyer's choice)
  • Display Delay:: -20 to 3400 µs
  • Warranty: 1 year
  • Brand: VTSYIQI
  • Transducer Connections:: BNC or LEMO
  • Dynamic range: more 40dB
  • Material Velocity:: 1000 to 20000m/s
  • Pulser:: Tunable Wave Pulser
  • Probe Delay/Zero Offset: 0 to 99.99µs
  • Measuring Range: 0 to 15000 mm, at steel velocity
  • resolving Power:: more 40dB
  • Modified Item: No
  • Custom Bundle: No
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • MPN: Ultrasonic Flaw Detector
  • Return shipping will be paid by: Buyer
  • Noise:: less than10%
  • Country/Region of Manufacture: China
  • Condition: New
  • Dynamic range:: more 40dB

    Description

    Industrial Ultrasonic Flaw Detector Crack Inclusions Pores Defect Detector Video
    Introduction
    This instrument is a portable industrial digital ultrasonic flaw detector that can detect, locate, evaluate and diagnose various defects (cracks,
    inclusions, pores
    , etc.) in the workpiece quickly, conveniently, without damage, and accurately. It can be used both in the laboratory and on the engineering site. This instrument can be widely used in manufacturing, iron and steel metallurgy, metal processing, chemical industry and other fields that require defect detection and quality control. It is also widely used in online safety inspection and Life assessment in the fields of aerospace, railway transportation, boilers and pressure vessels, etc.
    The instrument can be widely used in locating and sizing hidden cracks, voids, disbands, and similar discontinuities in welds, forgings, billets, axles, shafts, tanks and pressure vessels, turbines, and structural components.
    1.Features of the Instrument
    The core hardware is designed with ARM+FPGA, and the software uses a highly reliable multitasking operating system, which greatly improves the function, portability, durability and reliability of the instrument.
    This instrument uses a master-slave menu, and is designed with shortcut keys and a digital rotary knob.The instrument is light and portable, and can be held with one hand.
    2.Display
    Full-digital multi -color high-resolution (640
    ×
    480 pixels) multi-color TFT LCD display. The waveform display is more delicate and humane.
    4 operating interface styles can be selected according to the environment.
    The LCD with fast 60 Hz update. Able to display subtle waveform changes.
    The LCD brightness can be set freely.
    3.Shape
    The all-aluminum metal shell is
    strong and durable
    , and the electromagnetic shielding performance is very good.
    360-degree rotating damping bracket and rubber sheath are easy to use.
    Tempered glass panel, extremely hard, wear-resistant and scratch-resistant
    4.Screenshot and PDF flaw detection report
    Real-time screenshots of all pages and flaw detection reports, and save them as BMP pictures to U disk, which can be set as color or grayscale pictures.
    Export the flaw detection report as a PDF file and save it to a U disk for easy archiving and printing.
    All contents of the PDF file can be customized according to user needs.
    BMP pictures and PDF files can be viewed on a computer or mobile phone.
    5.Range
    Up to 15000mm in steel; range selectable in fixed steps or continuously variable. Suitable for use on large work pieces and in high-resolution measurements.
    6.Pulser
    Pulse Energy selectable among 100V,200V, 250V,300V,350V, 400V and 500V.
    Pulse Width tunable from 0.1µs to 0.5 µs to match the probes with different frequency.
    Pulse Repetition Frequency adjustable from 20 Hz to 2 KHz.
    Damping selectable among 50
    Ω、
    150
    Ω、
    250
    Ω
    and 500
    Ω
    for optimum probe performance
    Probe selection: single crystal probe, dual crystal probe, special angle probe, penetrating probe, climbing probe.
    7.Receiver
    Sampling

    16 digit AD Converter at the sampling speed of 320 MHz
    Rectification

    Positive Halfwave, Negative Halfwave, Fullwave and RF
    Analog Bandwidth: 0.2MHz to 20MHz capability with selectable frequency ranges (automatically set by the instrument) to match probe for optimum performance.
    Gain

    0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB.
    8.Gates
    Two fully independent gates offer a range of measurement options for signal height or distance using peak triggering.
    The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
    Gate Start: Variable over entire displayed range
    Gate Width: Variable from Gate Start to end of displayed range
    Gate Height: Variable from 0 to 99% Full Screen Height
    Alarms: Threshold positive/negative with LED Flash.
    9.Memory
    The instrument has a built-in large-capacity memory, and data and files will not be lost due to power failure of the instrument.
    Memory of 500 channel files to store calibration setups and probe parameter.
    Memory of 1000 wave report files to store A-Scan wave and settings.
    All the files can be stored, recalled and cleared.
    The channel settings and report files can be exported via U disk, and the information can also be stored in unlimited amounts via USB memory.
    10.Video Recorder
    Video Recorder is useful in many situations, it is very convenient for those who want to analyze the probing activities later.
    The instrument can record the test process and save it as a video file, which can be played back through the instrument or special software. It supports up to 10 video files, and each video file can be up to 5 minutes long.
    If you choose to save the video file to the U disk, the number and duration of the video file will not be limited.
    Recording and replaying the testing process provides great convenience for future study and analysis of flaw detection.
    Video playback supports pause, fast forward, fast rewind, and stop functions.
    Functions
    1.
    Auto calibration: Automated calibration of probe zero offset, probe angle (K value) and material velocity.
    2.
    Flaw Locating

    Live display Sound-path, Projection (surface distance), Depth, Amplitude,
    3.
    Flaw sizing: Automatic flaw sizing using AVG or DAC, speeds reporting of defect acceptance or rejection.
    4.
    Digital Readout and Trig. Function: Thickness/Depth can be displayed in digital readout when using a normal probe and Surface Distance and Depth are directly displayed when angle probe is in use.
    5.
    DAC/AVG

    The curve is automatically generated, and the sampling points can be compensated and corrected. The curve automatically floats with the gain, automatically expands with the detection distance, and automatically moves with the delay time. It can display the AVG curve of any aperture.
    6.
    AWS D1.1. Choosing this standard can reduce manual calculations and improve detection efficiency.
    7.
    Curved Surface Correction feature.
    8.
    Crack Height Measure function.
    9.
    Gate Magnify

    spreading of the gate range over the entire screen width.
    10.
    Video Recording and playback.
    11.
    Auto-gain function
    12.
    Envelope: Simultaneous display of live A-scan at 60 Hz update rate and envelope of A-scan display
    13.
    Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
    14.
    Peak mark: capture and mark the peak in real time
    15.
    Echo coding: display 1~9 echo display area in different colors, used to analyze the defect position.
    16.
    A Scan Freeze

    Display freeze holds waveform and test distance data.
    17.
    B Scan display feature. Intuitively display the defect shape of the workpiece and the detection result is more intuitive.
    Specifications
    1.
    Measuring Range:
    0 to 15000 mm, at steel velocity
    2.
    Pulse Repetition Frequency ranges from 20 Hz to 2000 Hz
    3.
    Material Velocity: 1000 to 20000m/s
    4.
    Pulse Repetition Frequency ranges from 20 Hz to 2000 Hz
    5.
    Dynamic range:
    more
    40dB
    6.
    System Linearity: Horizontal: +/-0.2% FSW,
    Vertical: 0.25% FSH, Amplifier Accuracy +/-1 dB.
    7.
    Resolving Power:
    more
    40dB
    8.
    Sensitivity Leavings:
    more
    50dB(Deep 200mmФ2 flat-bottomed hole)
    9.
    Reject (suppression): 0 to 80% full screen height
    10.
    Noise: less than10%
    11.
    Gate Monitors: Two independent gates controllable over entire sweep range
    12.
    Gain: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB.
    13.
    Bandwidth (amplifier bandpass ): 0.2 to 20 MHz
    14.
    Pulse Displacement:
    more
    32dB
    15.
    Display Delay: -20 to 3400
    µ
    s
    16.
    Probe Delay/Zero Offset : 0 to 99.99
    µ
    s
    17.
    Test Modes: Pulse echo, dual element and thru-transmission
    18.
    Pulser: Tunable Wave Pulser
    19.
    Pulse Energy: 100V, 200V, 250V, 300V, 500V selectable
    20.
    Rectification: Positive half wave, negative half wave, full wave, RF
    21.
    Units: Inch or millimeter
    22.
    Transducer Connections: BNC or LEMO
    23.
    Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
    24.
    Operating Temperature: -10

    to 50

    , Storage Temperature: -30

    to 50

    Standard Package:
    Host ,
    Straight Probe,
    Angle Probe
    4MHz,
    Probe Connecting Cable,
    Power Adaptor & Cable,
    PC Software,
    Communication Cable,
    User Manual,
    Instrument Case